Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 537
Filtrar
1.
BMC Oral Health ; 24(1): 269, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395853

RESUMO

BACKGROUND: The aim of this study is to evaluate the stress distributions of a primary molar tooth restored with a stainless steel crown (SSC) using resin and glass ionomer luting cements by Finite Element Analysis (FEA). METHODS: Original DICOM data of a primary molar was used to create a 3D model. One model was prepared as a tooth model with SSC. A 30 µm cement layer was used in model. Two different luting cements were tested in the study: self-cure adhesive resin cement, and glass ionomer cement. Vertical and oblique loads of 330 N were applied to simulate maximum bite force and lateral forces in the occlusal contact areas of the models. Maximum von Mises stress values in the models were evaluated as MPa. RESULTS: The maximum von Mises stress value was observed in the force application and general occlusal contact areas for all models. The maximum von Mises stress values were higher in the tooth model with SSC using self-cure adhesive resin cement (478.09 MPa and 214.62 MPa) than in the tooth model with SSC using glass ionomer cement (220.06 MPa and 198.72 MPa) in both vertical and oblique loading, respectively. CONCLUSIONS: Depending on the magnitude of the bite force on the SSC, fracture of the luting cement materials could occur if the stress exceeds the endurance limit of the luting cement. Cementation with glass ionomer cement may help to reduce stress levels in SSC restorations of primary molars in children.


Assuntos
Cimentos de Resina , Aço Inoxidável , Criança , Humanos , Cimentos de Resina/uso terapêutico , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro/uso terapêutico , Coroas , Dente Molar , Teste de Materiais
2.
J Prosthet Dent ; 131(2): 251.e1-251.e7, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38368000

RESUMO

STATEMENT OF PROBLEM: Little is known about the effect of different composite resin cements on the bond strength of prefabricated and milled glass fiber post-and-cores. PURPOSE: The purpose of this in vitro study was to compare the push-out bond strengths of root dentin and standard, relined, or computer-aided design and computer-aided manufacturing (CAD-CAM) glass fiber post-and-cores luted with conventional, universal, or self-adhesive composite resin cement. MATERIAL AND METHODS: Post spaces were prepared in 90 premolars. Standard and relined prefabricated and CAD-CAM-milled glass fiber post-and-cores were luted with conventional (RelyX ARC; 3M ESPE), universal (RelyX Ultimate; 3M ESPE), and self-adhesive (RelyX U200; 3M ESPE) composite resin cement (n=10). All specimens were thermally aged (5000 cycles at 5°C and 55°C with a 20-second dwell time) and mechanical fatigue (1 000 000 cycles at 2 Hz, 50-N load). The specimens were sectioned perpendicularly to the root long axis into 1-mm-thick sections (apical, middle, and cervical root thirds), the push-out bond strength was determined, and the mode of failure recorded. Data were submitted to the Kruskal-Wallis test followed by the Bonferroni-Dunn multiple comparison test (α=.05). RESULTS: Push-out bond strength values did not differ (P>.05) among posts at the same root thirds. Standard posts showed higher bond strength than CAD-CAM at the apical third for data grouped by composite resin cements (P<.001). The cervical root thirds had higher bond strength than the apical thirds (P<.05). The cervical, middle, and apical root thirds showed decreasing bond strength values for each type of post for data grouped by composite resin cement (P<.001). Adhesive failures at the dentin-cement interface were predominant. CONCLUSIONS: The type of posts and cements did not affect the bond strength of glass fiber posts. The cervical root thirds had better bonding performance than the apical thirds.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/uso terapêutico , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Vidro , Cimentos de Ionômeros de Vidro , Desenho Assistido por Computador , Teste de Materiais , Dentina , Cavidade Pulpar , Análise do Estresse Dentário
3.
Oper Dent ; 49(2): 222-230, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38349820

RESUMO

The aim of this study was to evaluate the push-out bond strength and the failure mode of single adjustable posts (SPLENDOR SAP), anatomical posts (AP), or computer-aided design/computer-aided manufacturing (CAD-CAM) posts cemented to flared root canal dentin with self-adhesive dual-cure resin cement. Thirty single-rooted premolars received endodontic treatment with gutta-percha and a calcium hydroxide-based endodontic cement. After 24 hours, the canal spaces were enlarged with burs. The tooth specimens were divided equally into three groups (n=10), according to the glass fiber post (GFP) system: AP-prefabricated GFP (Reforpost #2, Angelus) was relined with composite resin (Filtek Z350 XT, 3M ESPE); SPLENDOR SAP-GFP was used with a glass fiber sleeve to adjust the adaptation (Splendor SAP, Angelus); and CAD-CAM-a resin pattern was obtained and scanned to produce a CAD-CAM GFP (Fiber CAD Lab, Angelus) milled using a subtractive technique. The three GFP systems were cemented with self-adhesive resin cement (Rely X U200, 3M ESPE). The roots were fixed to an acrylic resin plate used to section them into specimens of cervical, middle, and apical thirds. Then, the slices were attached to a universal testing machine to perform the push- out test at a speed of 0.5 mm/min and a load of 50 Kgf. The posttest specimens were examined under a stereoscopic microscope to evaluate the failure mode. The bond strength variable was analyzed using a generalized linear model, following a split-plot design. Failure mode analysis was performed using Fisher exact test. The significance level adopted was 5%. There was no significant difference among the GFP systems or among the thirds, in terms of bond strength (p>0.05), nor was there any significant association between the systems and the failure mode (p>0.05). Most specimens presented mixed or adhesive failure between resin cement and dentin. It was concluded that the bond strength to flared root dentin was not influenced by the GFP system or the root third.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina/uso terapêutico , Colagem Dentária/métodos , Cavidade Pulpar , Cimentos Dentários , Vidro , Teste de Materiais , Dentina
4.
J Prosthet Dent ; 131(3): 458.e1-458.e7, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38182455

RESUMO

STATEMENT OF PROBLEM: Resin-bonded prostheses, including interim resin-bonded prostheses, are effective in preserving tooth structure compared with other types of fixed dental prostheses for the replacement of missing teeth. However, loss of retention remains a notable concern with these types of prostheses. PURPOSE: The purpose of this in vitro study was to investigate the influence of glass-ceramic type, resin type, and surface finish on the shear bond strength (SBS) to the CAD-CAM ceramics used to fabricate interim resin-bonded prostheses. MATERIAL AND METHODS: Eighty 10×2-mm glass-ceramic disks were fabricated by using a diamond saw (IsoMet 1000), 40 from feldspathic porcelain blocks (Vita Mark II) and 40 from lithium disilicate blocks (IPS e.max CAD). Half of the specimens in each group were left with a dull or matte surface finish after cutting, while the other half were glazed with an add-on glaze (VitaAkzento Plus Glaze Spray and IPS e.max CAD Glaze Spray, respectively). The disks were mounted in acrylic resin, and each group was subdivided into 2, with 1 receiving a photopolymerized resin cement (RelyX Veneer) and the other receiving a flowable composite resin (Filtek Supreme Ultimate Flow) to form 2.38×2-mm cylinders. SBS was determined using a universal testing machine (Instron 4411) in accordance with the International Organization for Standardization (ISO) 29022:2013 standard, and failure modes were analyzed by using a stereomicroscope with ×40 magnification. The data were analyzed with a 3-way analysis of variance and Tukey post hoc analysis. The chi-squared test was used to analyze the failure mode (α=.05 for all tests). RESULTS: Ceramic type, resin type, and surface finish significantly impacted SBS (P<.001, P=.003, P<.001, respectively). Lithium disilicate showed higher SBS than feldspathic porcelain, and flowable composite resin exhibited higher SBS than resin cement. Glazed surfaces displayed lower SBS compared with the dull or matte surfaces. The combinations among the 3 materials also impacted SBS (P=.03). In addition, the combinations between ceramic type and surface finish affected SBS (P<.001), regardless of resin cement type. No other combinations affected the SBS (P>.05). The mode of failure was different among the groups (P<.001). In comparison with all other groups, cohesive failures were most prevalent in feldspathic porcelain with a dull or matte surface finish, regardless of the resin type used. CONCLUSIONS: The SBS to glass-ceramics was influenced by ceramic material, resin cement type, and surface finish. Flowable composite resin showed higher SBS than resin cement. A dull or matte surface finish exhibited greater bond strength than a glazed surface. Lithium disilicate had higher SBS than feldspathic porcelain.


Assuntos
Colagem Dentária , Porcelana Dentária , Porcelana Dentária/química , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Propriedades de Superfície , Cerâmica/uso terapêutico , Cerâmica/química , Desenho Assistido por Computador
5.
Oper Dent ; 49(1): 52-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019213

RESUMO

The present study aimed to evaluate the influence of application mode on the short-term microshear bond strength longevity of self-etching and universal adhesive systems to enamel, the failure mode, and the resulting enamel surface micromorphology. Ninety enamel surfaces were obtained from sound third molars, planed, and randomly assigned to nine groups, according to the application mode and the adhesive system (n=10). There were three primer application modes: according to the manufacturer's recommended application time (control), using double the application time recommended for the primer and selective enamel etching. The adhesive systems used were: Clearfil SE Bond (Kuraray), FL-Bond II (SHOFU), and Futurabond U (Voco). At least two resin-bonded composite cylinders (Grandioso Light Flow, Voco) were placed on each enamel surface, and then evaluated for microshear bond strength at 24 hours and 180 days of storage in solution body fluid (SBF) at pH 7.4. Failure modes were evaluated with a stereoscopic microscope at 20× magnification. A micromorphological analysis of the enamel surface was performed under a scanning electron microscope at 5000× magnification before and after the treatments. Mixed models for repeated measures over time showed significant interaction among application modes, adhesive systems, and time periods (p=0.0331). The bond strength of FL-Bond II adhesive to enamel observed after performing selective enamel etching was significantly higher than that observed after applying the control treatment (p=0.0010) at both 24 hours and 180 days. However, no significant difference was observed between the application of this same adhesive at double the time recommended by the manufacturer and the other two application modes (p>0.05). There was also no significant difference in the microshear bond strength for the enamel treatments applied using Clearfil SE Bond and Futurabond U (p>0.05). A significant reduction in bond strength to enamel was observed at the 180-day storage time for all the adhesive systems when selective enamel etching was performed (p<0.0001). No significant association was observed between the adhesive system failure mode and the enamel treatments (p=0.1402 and p=0.7590 for 24 hours and 180 days, respectively). The most prevalent failure was the adhesive type.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/química , Colagem Dentária/métodos , Condicionamento Ácido do Dente/métodos , Resinas Compostas/química , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Esmalte Dentário , Teste de Materiais , Resistência ao Cisalhamento , Adesivos Dentinários/química
7.
J Dent ; 142: 104823, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145806

RESUMO

OBJECTIVE: To evaluate the effect of prolonged (P) polymerization time of a universal adhesive system applied in etch-and-rinse (ER) or self-etch (SE) strategies on the clinical performance of restorations in non-carious cervical lesions (NCCLs), after 36 months of clinical service. METHODS: A total of 140 restorations were randomly placed in 35 subjects according to the polymerization time groups: ER (10 s); ER-P (40 s); SE (10 s); and SE-P (40 s) at 1,200 mW/cm2. Composite resin was placed incrementally. The restorations were evaluated immediately and after 6, 12, 18, and 36 months using the FDI criteria. Data were analyzed using the Kaplan-Meier survival test for retention loss, and the Kruskal-Wallis' test for secondary outcomes (α = 0.05). RESULTS: After 36 months, 19 restorations were lost: ER 6, ER-P 2, SE 9, SE-P 2. The retention rates were 82.3% for ER; 94.1 % for ER-P; 73.5 % for SE; and 94.1 % for SE-P, with a significant difference between ER vs. ER-P and SE vs. SE-P, as well as ER vs. SE-P and ER-P vs. SE (p < 0.0001). Minor defects were observed in 18 restorations for the marginal staining criteria: ER 5, ER-P 2, SE 8, SE-P 3; and in 33 restorations for the marginal adaptation criteria: ER 11, ER-P 4, SE 12, and SE-P 6 (p > 0.05). No restorations showed recurrence of caries or postoperative sensitivity. CONCLUSIONS: A prolonged polymerization time of 40 s improves the clinical performance of the universal adhesive for both adhesive strategies evaluated, even after 36 months. CLINICAL SIGNIFICANCE: Prolonging the polymerization time of a universal adhesive from 10 to 40 s has been shown to improve its clinical performance when used in NCCLs.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Resinas Compostas/uso terapêutico , Adaptação Marginal Dentária , Falha de Restauração Dentária , Restauração Dentária Permanente , Adesivos Dentinários/uso terapêutico , Polimerização , Cimentos de Resina/uso terapêutico , Colo do Dente/patologia , Método Duplo-Cego
8.
Odovtos (En línea) ; 25(3): 82-98, Sep.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1529071

RESUMO

Abstract To evaluate the microtensile bond strength (µTBS) of two resin cements to 3D printed and milled CAD/CAM resins used for provisional fixed partial dentures. Blocks (5 x 5 x 5 mm) of three 3D-printed resins (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) were printed (Photon, Anycubic Technology Co.). A milled material (VitaCAD-Temp, VITA) was used as control. Half the specimens were sandblasted and the rest were untreated. Two blocks were bonded with the corresponding resin cement: PanaviaV5 (Kuraray Noritake) and RelyX Ultimate (3M Oral Care). After 24 hours, the bonded blocks were sectioned into 1 x 1 mm side sticks. Half the beams were tested for µTBS and the other half was thermocycled (5000 cycles, 30s dwell-time, 5s transfer time) before µTBS testing. A four way Generalized Linear Model (material*sandblasting*cement*aging) analysis was applied. VITA exhibited the lowest µTBS, regardless of the cement, sandblasting and thermocycling. Sandblasting significantly improved the µTBS of VIT, especially after aging, but did not improve the µTBS of 3D printed resins. Sandblasting was not beneficial for 3D printed resins, although is crucial for adhesive cementation of milled temporary resins. Airborne particle abrasion affects the integrity of 3D-printed resins, without producing a benefit on the microtensile bond strength of these materials. However, sandblasting is crucial to achieve a high bond strength on milled temporary resins.


Resumen Evaluar la resistencia adhesiva en microtracción (µTBS) de dos cementos resinosos a resinas CAD/CAM impresas y fresadas indicadas para restauraciones provisionales. Bloques (5 x 5 x 5mm) de tres resinas impresas (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) y una resina fresada (VitaCAD-Temp, VITA) fueron fabricados. La mitad de los especímenes fueron arenados y el resto no recibió tratamiento mecánico. Dos bloques con condiciones de tratamiento iguales fueron cementados con cemento resinoso (PanaviaV5 / Kuraray Noritake y RelyX Ultimate / 3M Oral Care). Después de 24 horas los bloques fueron seccionados en palitos de 1 mm² de área. En la mitad de los especímenes se midió la TBS inmediatamente y el resto fue termociclado (5000 ciclos, 30s remojo, 5s transferencia) antes de la prueba de TBS. Se aplica un análisis estadístico por Modelo Linear General con 4 factores (material*arenado*cemento*termociclado). La resina VITA presentó la menor µTBS, independientemente del cemento usado, el arenado y el termociclado. Sin embargo, el arenado aumentó la µTBS de VIT, especialmente después del termociclado. Por otro lado, el arenado no resultó en un aumento significativo de la µTBS de las resinas impresas. El arenado no fue beneficiosos para las resinas impresas, aunque es un paso crucial para la cementación adhesive de las resinas fresadas. El arenado afecta la integridad de las capas de las resinas impresas, sin generar un beneficio en la TBS.


Assuntos
Desenho Assistido por Computador/instrumentação , Cimentos de Resina/uso terapêutico , Cemento Dentário , Impressão Tridimensional/instrumentação
9.
PeerJ ; 11: e16469, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38025677

RESUMO

Background: This study aimed to evaluate the load capacity of maxillary central incisors with simulated flared root canal restored with different fiber-reinforced composite (FRC) post cemented with either self-adhesive or self-etch resin cement and its mode of fracture. Methods: Sixty-five extracted maxillary incisors were decoronated, its canal was artificially flared and randomly categorized into group tFRC (tapered FRC post) (n = 22), mFRC (multi-FRC post) (n = 21), and DIS-FRC (direct individually shaped-FRC (DIS-FRC) post) (n = 22), which were further subdivided based on cementation resin. The posts were cemented and a standardized resin core was constructed. After thermocycling, the samples were loaded statically and the maximum load was recorded. Results: The load capacity of the maxillary central incisor was influenced by the different FRC post system and not the resin cement (p = 0.289), and no significant interaction was found between them. Group mFRC (522.9N) yielded a significantly higher load capacity compared to DIS-FRC (421.1N). Overall, a 55% favorable fracture pattern was observed, and this was not statistically significant. Conclusion: Within the limitation of the study, it can be concluded that prefabricated FRC posts outperform DIS-FRC posts in terms of the load capacity of a maxillary central incisor with a simulated flared root canal. The cementation methods whether a self-adhesive or self-etch resin cement, was not demonstrated to influence the load capacity of a maxillary central incisor with a flared root canal. There were no significant differences between the favorable and non-favorable fracture when FRC post systems were used to restored a maxillary central incisor with a flared root canal.


Assuntos
Fraturas Ósseas , Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Incisivo/cirurgia , Cimentos de Resina/uso terapêutico , Cimentação/métodos , Cavidade Pulpar/cirurgia , Resinas Compostas/uso terapêutico , Estresse Mecânico , Resinas Vegetais
10.
BMC Oral Health ; 23(1): 810, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898802

RESUMO

BACKGROUND: The purpose of this study was to evaluate remineralisation and its effect on microtensile bond-strength of artificially induced caries affected dentin (CAD) when treated with a commercial universal adhesive modified with poly(amidoamine) dendrimer (PAMAM) loaded mesoporous bioactive glass nanoparticles (A-PMBG). MATERIAL AND METHODS: Mesoporous bioactive glass nanoparticles (MBG) were synthesised using sol-gel process, where PAMAM was loaded (P-MBG) and added to commercial adhesive at different weight percentages (0.2, 0.5, 1 and 2 wt%). First, rheological properties of commercial and modified adhesives were evaluated. The effect of remineralization/hardness and microtensile bond-strength (MTBs) of those samples that mimicked the rheological properties of commercial adhesives were evaluated using Vickers hardness tester and universal testing machine respectively. Scanning-Electron microscope was used to visualize failed samples of MTBs and remineralization samples. Both evaluations were carried out at 1-,3 and 6-month intervals, samples being stored in stimulated salivary fluid during each time interval. RESULTS: Addition of nanoparticles altered the rheological properties. With increase in the weight percentage of nanoparticles in commercial adhesive, there was significant increase in degree of conversion, viscosity and sedimentation rate (p < 0.05). The 0.2 and 0.5 wgt% groups closely mimicked the properties of commercial adhesive and were evaluated for remineralization and MTBs. After 6 months, 0.2wgt% group showed increased MTBs (p < 0.05) and 0.5wgt% group increased remineralization/hardness (p < 0.05). CONCLUSION: The complex of PAMAM-MBG-Universal adhesive can remineralize the demineralised CAD thereby improving its bond-strength when evaluated for up to 6-months.


Assuntos
Colagem Dentária , Cárie Dentária , Nanopartículas , Humanos , Cimentos Dentários/uso terapêutico , Suscetibilidade à Cárie Dentária , Dentina , Nanopartículas/uso terapêutico , Cárie Dentária/terapia , Resistência à Tração , Teste de Materiais , Cimentos de Resina/uso terapêutico
11.
J Dent ; 139: 104740, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37816489

RESUMO

OBJECTIVE: To evaluate the effects, of using silane coupling agent within the procedures of repairing old composite restorations with or without sandblasting their surfaces, on the clinical performance of repaired composite restorations. METHODS: The study involved repairing 130 Class I and II defective composite restorations. After recurrent caries removal, the repair process included etching with 37 % phosphoric acid, Adper Single Bond 2 application for bonding and Filtek Z250 composite for restoring all defects. The restoration surfaces were subjected to one of the following additional surface treatments within the repair process: Control: No additional treatment; the Silane-Adhesive treatment: A separate step involved the application of a silane coupling agent after acid etching; and the Sandblast-Silane-Adhesive treatment: included intra-oral sandblasting of old composite surfaces followed by silane application. Two calibrated examiners evaluated all repaired restorations according to a modified USPHS criteria after 6 months. Comparisons of the clinical performance between the treatment groups were made using Chi-square test, while responses to cold tests before and after repair treatment were made using Wilcoxon's Signed Rank's (α = 0.05). RESULTS: Of 130 cases, only 116 cases turned up for evaluation. The primary reasons for composite repair were recurrent caries and anatomical deficiencies. No statistically significant differences were found between the groups for all clinical criteria (p > 0.05). The control group experienced one total and two partial retention losses. CONCLUSIONS: The application of a silane coupling agent, with or without intra-oral sandblasting, demonstrated no improvement on the clinical performance of repaired posterior composites after 6-months. CLINICAL SIGNIFICANCE: Surface treatment of defective composite restorations using silane with intra-oral sandblasting within their repair process offered marginal improvement in their clinical performance over conventional etching technique, but insignificantly so. Repair reduced exaggerated cold test responses and eliminated POS within 6-months. Repair reduces cold sensitivity and promotes restoration longevity. This clinical trial was registered at ClinicalTrials.gov with the registration number NCT06005571.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Silanos , Propriedades de Superfície , Materiais Dentários/uso terapêutico , Materiais Dentários/química , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Cárie Dentária/cirurgia , Resistência à Tração , Restauração Dentária Permanente , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química
12.
Compend Contin Educ Dent ; 44(8): e5-e9, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37708047

RESUMO

Dentists frequently encounter the need to cement indirect restorations in clinical situations that are less than ideal, and the longevity and predictability of the indirect restorative materials used in such cases is largely predicated on the chemical and/or mechanical bond formed between the natural tooth or abutment and the cement. These non-ideal scenarios have been a significant driver in the continued evolution of self-adhesive resin cements (SARCs) with added functional monomers, such as 10-MDP. This article discusses three real-world case studies in which a newly developed universal SARC was utilized and combined with the use of an optional adhesive-enhancing primer that employs a proprietary "touch-cure" technology, or a light-cured adhesive, to improve the bond strength of the resin cement and enhance patient outcomes.


Assuntos
Prostodontia , Cimentos de Resina , Humanos , Cimentos de Resina/uso terapêutico , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro , Cimentos Ósseos
13.
J Prosthet Dent ; 130(4): 604.e1-604.e5, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37633730

RESUMO

STATEMENT OF PROBLEM: Implant manufacturers have introduced titanium base (Ti-Base) abutments with increased abutment heights, ostensibly, to increase the retention of the bonded restoration and to improve overall strength. However, evidence regarding the effects of increasing Ti-Base height on improving retention is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different Ti-Base abutment heights on the retention of zirconia implant-supported crowns. MATERIAL AND METHODS: Thirty Ti-Base abutments of the same diameter and heights of 3.5 mm (n=10), 4.5 mm (n=10), and 5.5 mm (n=10), were used for testing. Zirconia restorations were cemented onto the Ti-Base abutments with a resin cement after treatment with a 10-methacryloyloxydecyl dihydrogen phosphate primer by a single operator using a positioning device. The zirconia-Ti-Base restorations were tightened to an implant analog embedded in an autopolymerizing resin block. The specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using 1-way analysis of variance with the Tukey method for pairwise comparisons. RESULTS: The abutment height had a significant effect on retention (P=.010). Ti-Base abutments of 4.5 and 5.5 mm had significantly greater retention than Ti-Base abutments of 3.5 mm (P=.020, P=.040, respectively). However, Ti-Base abutments of 4.5 and 5.5 mm in height were statistically similar (P=.890). CONCLUSIONS: An increase in the height of Ti-Base abutments above the standard 3.5 mm height significantly improved the retention of the overlying restoration.


Assuntos
Coroas , Titânio , Zircônio , Cimentos de Resina/uso terapêutico , Dente Suporte , Teste de Materiais , Análise do Estresse Dentário , Projeto do Implante Dentário-Pivô
14.
Oper Dent ; 48(5): E106-E118, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37503637

RESUMO

PURPOSE: To assess the clinical performance of restorations with ground and unground enamel for diastema closure. METHODS AND MATERIALS: Twenty-four patients attended and received two to ten composite build-ups for diastema closure. The restorations were performed separately by grinding and not grinding the enamel on the proximal surfaces on symmetric teeth. A nanofill direct composite (Filtek Ultimate Universal Restorative System, 3M ESPE, St Paul, MN, USA) was used with a three-step etch-and-rinse adhesive (Scotchbond Multi-Purpose, 3M ESPE) for restorations. Restorations were evaluated according to the modified United States Public Health Service (USPHS) criteria at baseline and 1-, 2-, 3-, 4-, and 5-year recalls. RESULTS: The cumulative success rate of direct composite build-up with ground and unground enamel was 100% and 88.7%, respectively. Six restorations with unground enamel failed due to fracture. No significant difference was found between the restorations with ground enamel and unground enamel with regard to the evaluation criteria. CONCLUSION: The 5-year success rates of restorations with ground and unground enamel were excellent. The success rate of restorations with ground enamel was higher than that of restorations with unground enamel. Fracture was the reason for failure in the restorations with unground enamel.


Assuntos
Cimentos Dentários , Diastema , Humanos , Cimentos Dentários/uso terapêutico , Cimentos Dentários/química , Adesivos Dentinários/química , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Seguimentos , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Esmalte Dentário , Restauração Dentária Permanente/métodos
15.
Oper Dent ; 48(5): 500-512, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37503689

RESUMO

OBJECTIVES: To evaluate the absence of 2-hydroxyethyl methacrylate (HEMA) on the adhesive properties with enamel and dentin of universal adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP). METHODS AND MATERIALS: One hundred and twelve caries-free third molars were used to test adhesion to dentin (n=64) and enamel (n=48). For each substrate, teeth were divided into eight experimental groups: four different adhesives each using two adhesive strategies. The adhesives used were: (1) Scotchbond Universal (SBU, 3M Oral Care, St Paul, MN, USA) as a HEMA-containing universal adhesive; (2) Gluma Bond Universal (GBU, Kulzer, Hanau, Germany); (3) Solare Universal Bond (SUB, GC, Tokyo, Japan); and (4) Zipbond Universal (ZIP, SDI, Victoria, Australia) as HEMA-free universal adhesives. The adhesive strategies used were etch-and-rinse (ER) and self-etch (SE). For dentin tests, the occlusal third of the crown of all teeth was removed and an adhesive protocol was applied. After completing the restoration, specimens were sectioned into bonded sticks (0.8 mm 2) and tested for microtensile bond strength (µTBS), in situ degree of conversion (DC), and nanoleakage (NL) by scanning electron microscopy. For enamel tests, teeth were sectioned into four parts (buccal, lingual, and proximal), and an adhesive protocol was applied. After completing the restoration, the specimens were tested for their microshear bond strength (µSBS). For in situ degree of conversion (DC) and nanoleakage (NL) evaluation of enamel, the specimens were sectioned in slices to be evaluated. The data for each substrate were subjected to two-way ANOVA and Tukey's test (α=0.05) for each property evaluated. RESULTS: The SBU and ZIP adhesives showed the highest µSBS, and DC (dentin and enamel) and lower NL (dentin) values compared to GBU and SUB (p=0.001). However, SBU showed better results in terms of µTBS and µSBS (SE strategy), and DC (dentin and enamel) than ZIP. Strategy ER presented higher values of µTBS and µSBS when compared to strategy SE (p=0.001), except for SBU. CONCLUSION: The effect of the absence of HEMA in commercial universal adhesive systems on enamel and dentin adhesive properties appears to be material-dependent.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/uso terapêutico , Cimentos Dentários/química , Dentina , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Metacrilatos/química , Resinas Compostas/química , Teste de Materiais , Resistência à Tração , Adesivos Dentinários/química
16.
Clin Exp Dent Res ; 9(6): 1096-1111, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37427500

RESUMO

OBJECTIVE: The aim of this study was to review the selection criteria of resin cements for different types of partial coverage restorations (PCRs) and investigate if the type of restorations or restorative materials affect the type of selected resin cement. MATERIALS AND METHODS: An electronic search (1991-2023) was performed in PubMed, Medline, Scopus, and Google Scholar databases by combinations of related keywords. RESULTS: A total of 68 articles were included to review the selection criteria based on the advantages, disadvantages, indications, and performance of resin cements for different types of PCRs. CONCLUSIONS: The survival and success of PCRs are largely affected by appropriate cement selection. Self-curing and dual-curing resin cements have been recommended for the cementation of metallic PCRs. The PCRs fabricated from thin, translucent, and low-strength ceramics could be adhesively bonded by light-cure conventional resin cements. Self-etching and self-adhesive cements, especially dual-cure types, are not generally indicated for laminate veneers.


Assuntos
Cerâmica , Cimentos de Resina , Cimentos de Resina/uso terapêutico , Cimentos Dentários/uso terapêutico , Cimentação
17.
Int Dent J ; 73(6): 881-888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37385864

RESUMO

OBJECTIVE: The aim of this research was to investigate the effect of simplified adhesive strategies (self-etch vs selective enamel etch and 10- vs 20-second adhesive application time) on the marginal integrity in primary molars. METHODS: Forty deep class-II cavities were prepared in 40 extracted primary molars. The molars were divided into 4 groups based on the applied universal adhesive strategy as follows: groups 1 and 2: selective enamel etch with 20- or 10-second application time and groups 3 and 4: self-etch with 20- or 10-second application time. All cavities were restored with a sculptable bulk-fill composite restoration. The restorations underwent a thermomechanical loading (TML, 5-50 °C, 2-minute dwelling time, ×1000; 400,000 loading cycles, 1.7 Hz, 49 N). Marginal analysis before and after TML was conducted with scanning electron microscopy and the marginal integrity of each restoration was calculated as a percentage of continuous margins. A beta regression model was adopted to statistically analyse the data with a consequent pairwise comparison. RESULTS: The mean marginal integrity (% ± SD) of the restorations for each tested adhesive strategy after TML was as follows: selective enamel etch/20 seconds = 85.4 ± 3.9, self-etch/20 seconds = 85.3 ± 5.2, self-etch/10 seconds = 80.1 ± 8.2, and selective enamel etch/10 seconds = 80.0 ± 8.5. The difference between both adhesive strategies was not statistically significant at the same application time. The difference between both application times within the same adhesive strategy was statistically significant (P ≤ .01). CONCLUSIONS: Universal adhesives applied either in selective enamel etch or in self-etch mode result in comparable marginal integrities when restoring class-II cavities in primary molars. Shortened adhesive application time (10 seconds) could lead to a reduction in the marginal integrity in comparison to the recommended application time of 20 seconds.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Resinas Compostas/uso terapêutico , Cimentos Dentários/uso terapêutico , Cimentos de Resina/uso terapêutico , Teste de Materiais , Cárie Dentária/prevenção & controle , Dente Decíduo , Adaptação Marginal Dentária , Adesivos Dentinários/uso terapêutico , Restauração Dentária Permanente
18.
BMC Oral Health ; 23(1): 399, 2023 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-37328778

RESUMO

BACKGROUND: To investigate the effect of 0.3 M 1-ethyl-3(3-dimethylaminopropyl) carbodiimide (EDC) aqueous solution pretreatment on push-out bond strength (PBS) and matrix-metalloproteinases (MMPs) activity within radicular dentin when different post cementation strategies were employed. METHODS: One hundred and twenty monoradicular human teeth were endodontically treated and randomly divided into six groups, depending on the cementation strategy and root dentin pretreatment (n = 20): EAR: cementation with an etch-and-rinse adhesive (LuxaBond Total Etch, DMG) and resin cement (LuxaCore Z Dual, DMG); EAR/EDC: 1 min EDC pretreatment after etching + EAR; SE: cementation with a self-etch primer (Multilink Primer, Ivoclar Vivadent) and corresponding cement (Multilink Automix, Ivoclar Vivadent); SE/EDC: self-etch primer + EDC pretreatment + SE; SA: cementation with a universal self-adhesive cement (RelyX Universal, 3 M); SA/EDC: EDC pretreatment + SA. Slices were submitted to PBS test and interfacial nanoleakage evaluation 24 h after cementation or after thermocycling (40.000 cycles, 5-55 °C). To investigate the effect of EDC on MMPs activity, 4 additional first maxillary premolars per group were processed for in situ zymography analysis. Multivariate ANOVA and post hoc Tukey tests were used to analyze PBS values. The data from in situ zymography were analyzed with Kruskal-Wallis test and Dunn's pairwise multiple comparison procedures (α = 0.05). RESULTS: The variables "EDC pretreatment", "root region" and "thermocycling" significantly influenced PBS (p < 0.05), while the variable "cementation strategy" had no influence (p > 0.05). Thermocycling significantly reduced PBS in SE and SA groups (p < 0.05). EDC was effective in preserving PBS after artificial aging. EDC pretreatment significantly reduced enzymatic activity at baseline in EAR and SE groups, and in SA group after thermocycling (p < 0.05). CONCLUSIONS: The use of EDC prevents the reduction of bond-strength values after artificial aging and silences endogenous enzymatic activity within radicular dentin when different cementation strategies were employed.


Assuntos
Colagem Dentária , Humanos , Carbodi-Imidas/química , Dentina , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Metaloproteinases da Matriz , Teste de Materiais
19.
J Prosthet Dent ; 130(2): 256.e1-256.e12, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37357085

RESUMO

STATEMENT OF PROBLEM: Lack of conversion of resin cements for luting glass fiber posts in deeper levels of the root canal may compromise clinical performance. PURPOSE: The purpose of this in vitro study was to evaluate the effect of the degree of conversion on the surface properties of dual-polymerized resin cements used for cemented glass fiber posts according to the root level. MATERIAL AND METHODS: Fifty maxillary central incisor teeth were endodontically treated, and glass fiber posts were cemented using the following systems: self-adhesive dual-polymerized resin luting cement (RelyX U200) and dual-polymerizing flowable core and a post luting system (Rebilda DC) with a self-etching adhesive (Futurabond DC). The degree of conversion was determined via attenuated total reflectance and Fourier transform infrared spectroscopy, and surface microhardness and cement film thickness were measured. The intraradicular fit was evaluated with microscopy. All tests were performed in the coronal, middle, and apical third of the root canal. Statistical analysis was done with ANOVA and the multiple comparison Tukey test (α=.05). RESULTS: The degree of conversion was higher in the coronal third using Rebilda DC (65.3 ±4.8%) than RelyX U200 (38.7 ±5.3%) (P<.05); on both resin cements, these values decreased from the coronal to the apical third (30.9 ±3.7%, 61.9 ±8.7%, respectively). The cement film thickness was higher for RelyX U200 in the 3 thirds than for Rebilda DC; significant differences (P<.05) were recorded in both cementing systems in the coronal and apical thirds. In the middle third, no significant differences were observed (P>.05). The mean surface microhardness values increased in the coronal thirds and decreased with increasing root canal depth. The marginal seal in the coronal thirds and the intraradicular fit in the middle thirds showed closer adaptation; however, some tags were observed in the interface resin cement and radicular dentin. Gap and tag formations were observed in the apical third. CONCLUSIONS: Depending on the root canal third, the surface properties of dual-polymerized resin cements are influenced by the degree of conversion.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Colagem Dentária/métodos , Vidro , Cimentos de Ionômeros de Vidro , Propriedades de Superfície , Teste de Materiais , Cavidade Pulpar , Dentina
20.
Braz Oral Res ; 37: e052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255072

RESUMO

This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used. In the half to receive milled-CAD-CAM posts, tooth specimens were molded with acrylic resin to obtain replicas. These were scanned to enable the laboratory to produce the milled-CAD-CAM GFPs (Fiber CAD Lab, Angelus) by the subtractive technique. The other half of samples received prefabricated GFPs (Exacto, Angelus) (n=15). The GFPs were cemented with dual-cure resin cement (Panavia F2.0, Kuraray). Each root was sectioned into two slices per root region (cervical, middle, apical) that were subjected to the push-out BS test, in a universal testing machine. Failure mode (FM) was classified by scores. The BS data were submitted to generalized linear model analyses, while FM was analyzed using the chi-square test (a=0.05). BS showed no significant difference among the three ES (p > 0.05). BS was significantly higher for prefabricated (mean 10.84 MPa) versus milled-CAD-CAM GFPs (mean 6.94 MPa) (p <0.0001), irrespective of ES. The majority showed mixed failures. It could be concluded that type of ES did not affect BS of GFPs to dentin, and prefabricated-GFPs had higher bond-strength than customized-milled-CAD-CAM GFPs.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular , Teste de Materiais , Análise do Estresse Dentário , Materiais Restauradores do Canal Radicular/química , Vidro , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Desenho Assistido por Computador , Dentina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...